Customizing Your Dosimetry: Why One Size Doesn't Fit All
- Chad Gunther

- Sep 23
- 3 min read
In the world of preclinical research, an X-ray irradiator isn't just a machine…it's a precision instrument. But like a musical instrument, it has a unique "tone" that affects its performance. This tone is determined by its specific beam characteristics, and if your dosimetry system doesn't account for them, your data can be compromised.
With Dosequate™, we know that one size doesn't fit all. That's why our dosimetry system is not a generic tool; it is precisely tailored to your specific X-ray irradiator to ensure the highest level of accuracy and reproducibility for your studies.
The Unique Signature of Your Irradiator
Every X-ray irradiator, even from the same manufacturer, has a unique energy spectrum when set up for specific applications. This spectrum is a distribution of all the photon energies in the beam and is influenced by two primary factors:
Kilovoltage (kVp): The voltage applied to the X-ray tube determines the maximum energy of the photons.
Filtration: Filters, typically made of aluminum, copper, or other materials, are placed in the beam path to absorb low-energy photons. This process, known as "beam hardening," increases the mean photon energy and makes the beam more penetrating.
The mean photon energy is a critical parameter. A beam with a lower mean energy will deposit most of its dose in the superficial layers of tissue, while a higher-energy beam will penetrate deeper. If your dosimetry system isn't specifically calibrated for your machine's unique mean photon energy and filtration, your absorbed dose measurements will be inaccurate, leading to flawed research.
How Dosequate™ Customizes Your Dosimetry
To ensure our system is a perfect match for your irradiator, we conduct a detailed analysis to create a customized dosimetry solution.
Beam Characterization: We begin by characterizing your specific irradiator's beam. This involves analyzing the filtration used (e.g., thickness of aluminum or copper) and the voltage settings to determine the unique energy spectrum and mean photon energy. This step is a direct reality check on the machine's actual output.
Alanine Corrections: Our system uses alanine dosimeters, which are highly stable and reliable. However, even these must be precisely corrected for the specific energy of your beam. We apply a series of corrections and calibration factors to our alanine readings to ensure the absorbed dose we measure is accurate for your specific beam quality. This meticulous process ensures that our measurements are not just consistent but also traceable to national standards.
Physical Ground Truth: By performing this characterization and calibration with physical phantoms and alanine dosimeters, we provide a "ground truth" measurement that a theoretical Monte Carlo simulation alone cannot. We account for the real-world scatter and absorption effects within a realistic phantom, which are unique to your specific irradiator's beam and setup.
The Result: Confidence in Your Data
The output of our tailored process is a dosimetry system that removes the guesswork. It moves beyond a general dose check and provides you with the precise absorbed dose delivered to your target, accounting for every variable that influences the outcome.
This level of customization means you can publish your research with confidence, knowing that your dose data is not only accurate but also fully reproducible. For GLP studies, this traceability and precision are not just a benefit—they are a requirement for compliance. By tailoring our system to your unique irradiator, we ensure your data stands up to the most rigorous scrutiny.